Electromagnetic Flow
Electromagnetic Flow
Model: FEP311
Features:
The modular design of the ProcessMaster 300 offers the industry’s widest range of liners, electrodes and sizes to meet the needs of even the most demanding process applications in sectors as diverse as chemical, power, oil & gas, pulp & paper and metals & mining.

       - High measurement accuracy
       - Intuitive navigation and configuration
       - Backlit, high-contrast and configurable display
       - Detailed diagnostics for rapid decision making providing the right information to keep the process up and running
       - HART protocol is a standard with HygienicMaster 300
       - Pressure rating: PN10…100, Cl 150…600
       - Process connection: Flanges acc. to DIN/EN, ASME, JIS
       - Liner material: Hardrubber, softrubber, PTFE, PFA, ETFE
       - Max. Temperature: 180 °C ( 356 °F)
       - Ex-Approvals: ATEX, IEC Zone 1, 2 FM, CSA Div 1, 2, NEPSI Zone 1, 2, GOST
       - Verifikation: Softwaretool „ScanMaster
       - Diagnosis: Empty Pipe Detection
 
Application:

       - Chemical
       - Pharmaceutical
       - Water and Wastewater

 

       

Datasheet      Send to Friend


Thermall Mass Flow
Thermall Mass Flow
Model: FMT500-IG
Features:
Sensyflow FMT500-IG is a digital mass flow meter for air, gases and gas mixtures in process applications. The system is supplied with LCD display, integrated gas temperature measurement and totalizer functions. Communication and configuration is via the PROFIBUS DPV1 protocol or analog output / HART . Compact and remote versions allow for flexible mounting solutions. ATEX certified versions for Zone 0 and 1 applications are available.

       - Digital measuring system
       - PROFIBUS DPV1 or HART communication
       - Separate gas temperature measurement
       - Diagnostic functions
       - ATEX certification for Zone 0 and 1(gases) and 21 (dust)

Application:

       - Gas volume measurement in chemical industry and process technology
       - Compressed air balancing
       - Gas burner control systems
       - Biogas and activation air measurement in sewage plants
       - Gas measurement at air decomposers
       - Hydrogen measurement in the process

 

Datasheet      Send to Friend


Vortex and Swirl Flow
Vortex and Swirl Flow
Model: FS4000
Features: The TRIO-WIRL Swirlmeter provides all the advantages of the TRIO-WIRL V by needing shortest upstream/downstream distances, typical 3 x DN/1 x DN. As the Vortex flowmeter the Swirlmeter is based on the principle of Frequency measurement. 

The system has a freely configurable, two-line LC display for the actual flowrate and totalisation. Settings can be changed directly via 3 push buttons or via magnet sensors with closed housing. Additional to the 4-20mA analog signal a freely configurable switching output is already available. This can be used universally as pulse output, high-low alarms or for system supervision. TRIO-WIRL Swirlmeter are available as compact or remote design with 10m cable length. 

     - Size spectrum : DN 15 (1/2”) to DN 400 (16”)
     - Accuracy: max. ± 0.5 % of measured value for liquids, gases and steams
     - High dynamic measuring range 1:25
      - DSP converter with most modern digital filter technology for the safe detection of also       weakest sensor signals.
      - Optionally integrated PT100 e.g. for very economic massflow-measurement of saturated steam or for temperature monitoring/alarms.
 
Application:        - Liquids
       - Gases
       - Steams
Datasheet      Send to Friend


Pitot Tube
Pitot Tube
Model: FPD500
Features: PitoMaster is a Compact Averaging Pitot Flowmeter that combines a threaded or flanged-mounted insertion meter,an integral 3- or 5-valve manifold and a transmitter into a single, fully-codable insertion flowmeter. PitoMaster is supplied in two versions – one for volumetric flow and one for mass (or corrected volume) flow.
 
        - Low operating costs with small carbon footprint
          PitoMaster's low profile design creates minimal pressure losses, giving genuine savings in pumping/compression costs, with consequent reductions in energy usage and hence in CO2 emissions.

         - Economical metering in larger pipe sizes
           Low rate of cost increase with increasing pipe size provides metering at a low purchase cost for larger pipe sizes.

         - Large flow turndown means increased usability                 
           Unique profiled flats on probe define flow separation point, giving more constant flow coefficient at high velocities and a wide range of flow measurement (turndown).

          - Low cost, easy installation into existing pipelines
            Simple one- or two hole installation with mounting adapters supplied.
            No need to cut pipe and weld in flanges

Application:
Datasheet      Send to Friend


Coriolis Mass Flowmeters
Coriolis Mass Flowmeters
Model: FCM2000
Features: The CoriolisMaster FCM2000 is easy to install in any orientation and insensitive to vibrations or gas inclusions. Flexible connection sizes enable optimal adaptation to all processes. When high performance is needed the FCM2000 delivers:

      - Four accuracy classes in one device reduce product variability and warehousing costs.
      - Electronic module exchange without recalibration or reconfiguration.
      - Excellent density measurement with integrated concentration computation.
      - Sturdy design, strong signal level and optimized electronics the FCM2000 is insensitive to external vibrations and gas content in the fluid.
      - Direct mass flow measurement enables exact dosing of raw materials to increase efficiency and save resources.
 
Application:
Datasheet      Send to Friend


Orifice
Orifice
Model: FPD500
Features: OriMaster is a Compact Orifice Flowmeter that combines a wafer-mounted orifice carrier, integral manifold and transmitter into a single, fully-codable, orifice-based flowmeter. OriMaster is supplied in two versions – one for volumetric flow and one for mass (or corrected volume) flow.

          - One-stop source for the complete Orifice meter package
             Purchase all the components from one supplier using   a single ordering code, saving $$ in procurement and order-progressing activities. Ensures application suitability for the DP transmitter and the primary DP device.
    
         - Enhanced reliability, reduced maintenance
            As a one-piece flowmeter, pressure tested at the factory, problems during commissioning and operation associated with impulse line leakage - as well as installation errors - are virtually eliminated.

          - Low cost maintenance
         Pressure-tested in the factory for leak prevention.
            Removable orifice plates for on site, low cost solutions to changes in process data or element wear/damage.
 
Application:
Datasheet      Send to Friend